Home » How to choose a fill-level sensor for drop-off containers

How to choose a fill-level sensor for drop-off containers: the buyer's guide

A fill-level sensor measures how full a waste container is and sends this data to a monitoring platform. The market includes many manufacturers and integrators, with very different technologies, networks and business models. This guide lists the criteria to check before buying, and the questions to ask every supplier, whoever they are.

1. Start from the use case, not from the sensor

Before comparing data sheets, decide what the local authority will do with the data. Three use cases are common in the field:

  • diagnosis: understanding how drop-off points (bring banks) are used, in order to move, add or remove containers and adjust collection frequencies;
  • dynamic route planning: collecting only the containers that need it;
  • overflow alerts: stepping in before waste piles up at the foot of the containers.

The use case determines how many sensors are needed, where they go and how much integration is required. For example, the Grand Chambéry conurbation (France) used movable sensors to diagnose its drop-off points, cross-checking the data with field surveys and the on-board software of its trucks. Some drop-off points were moved, a new one was created and some collection frequencies were reduced (source: Banque des Territoires fact sheet, in French).

2. The measurement technology, depending on the waste stream

The waste stream determines which technology is the most reliable. A sensor suited to packaging is not necessarily suited to glass or household waste.

Measurement technologies and suitable waste streams
Technology Strengths Points to check Typical streams
Ultrasound Proven, widespread technology Centimetre-level accuracy, disturbed by irregular shapes and container walls General use
Time-of-flight laser (ToF) Very accurate, narrow beam Sensitive to dirt on the measurement window Packaging, paper, cardboard, textiles
Radar Reliable despite dirt and condensation Check the measuring range (minimum and maximum distance) Glass, household waste

What to check: the measuring range compared with the height of your containers (above-ground, semi-underground or underground), the stated accuracy, and the ability to filter out wrong readings (a bag stuck in the chute, an object lying on the sensor).

3. The communication network

Four networks are commonly used: LoRaWAN (public or private), Sigfox, LTE-M and NB-IoT. The right choice depends on the territory and on existing infrastructure. A local authority that already runs a private LoRaWAN network can use it, as Grand Chambéry did. For underground containers, signal penetration is decisive. Our IoT network comparison details the differences.

What to check: actual coverage at your sites (a test on a few sites is recommended), the cost of the network subscription, and whether you can change network without changing sensor.

4. Real battery life

A stated battery life only makes sense with its assumptions: number of measurements per day, number of transmissions per day, network used and temperature. The same sensor can last twice as long on one network as on another.

What to check: the calculation assumptions, whether the battery can be replaced on site and at what cost, and whether the measurement frequency can be adjusted remotely.

5. Ruggedness

The inside of a waste container is a hostile environment: humidity, decomposition gases, impacts, high-pressure washing and temperature swings.

What to check: the water and dust protection rating (IP67, IP68, or IP69K for high-pressure washing), the impact resistance rating (IK), the operating temperature range, the mounting system and its compatibility with your container models.

6. Platform and interoperability

A sensor is useless if its data is not used. The platform must be easy for the teams to use and must connect to existing tools: route planning or truck tracking software, billing software, geographic information system.

What to check: a documented API, data export, configurable alerts, automatic reports, role-based access rights, and who owns the data at the end of the contract.

7. Total cost of ownership

The purchase price of the sensor is only part of the cost. Over the lifetime of the project, add up hardware, installation, platform subscription, connectivity, battery replacement and maintenance. As a public example, the Grand Chambéry fact sheet states €159 per sensor in investment and €75 per sensor per year for platform access.

8. The procurement framework

Starting with a pilot on a few dozen sites validates network coverage, measurement reliability and actual use by the teams. In France, public procurement rules allow innovative solutions to be bought without advertising or competitive tendering below €100,000 excluding VAT, a scheme extended in 2024 to young innovative companies (see our article, in French).

9. Standards and compliance

  • CE marking and the RED directive for radio equipment.
  • RoHS and REACH for hazardous substances.
  • End of life (WEEE): the manufacturer should belong to an approved take-back scheme for used sensors.
  • EN 14803: the European standard on identification and determination of the quantity of waste, useful if the project includes identifying users or containers (pay-as-you-throw).

Questions to ask every supplier

  1. Which measurement technology for each of my waste streams, and what measuring range?
  2. Which networks are available, and can I change network during the contract?
  3. What battery life, based on which measurement and transmission assumptions?
  4. What IP and IK ratings, and what temperature range?
  5. Does the sensor fit all my container models, and how long does installation take?
  6. Which API and which connectors to my existing software?
  7. What total cost over 5 or 10 years, including batteries and subscriptions?
  8. Who owns the data, and how do I get it back at the end of the contract?
  9. Which comparable local authorities can you cite as references, with measured results?
  10. Where is the sensor designed and manufactured, and how is its end of life handled?

FAQ

Do all containers need a sensor?

No. For a diagnosis, a few dozen movable sensors can be enough. For route planning, equip the containers whose fill rate varies the most or that are the most expensive to collect.

Which technology for glass?

Glass is a dirty and noisy waste stream: radar is generally the most reliable.

How do you compare two offers?

By comparing the total cost over the lifetime (hardware, installation, platform, network, batteries) rather than the sensor price alone, and by testing both solutions on a few sites.

This guide is published by BH Environnement, which designs the Heywaste sensors. The criteria above apply to every solution on the market.

Cyril Pradel

About the author

Cyril Pradel

Deputy CEO of the BH group, founder of Heyliot

Cyril Pradel founded Heyliot (now BH Environnement) in 2017 and ran it for eight years. He led the design and French manufacturing of the Heywaste fill-level sensors and filed a patent on laser measurement of container fill levels. With more than twenty years in information systems, networks and IoT, he is now Deputy CEO of the BH group (BH Technologies and BH Environnement), in charge of digital transformation and AI.

All his guides · View LinkedIn profile

Would you like a free demo?

We will be happy to give you a free demonstration of our solution and discuss your project.